Implantation of the left ventricular pacemaker lead after successful balloon angioplasty for coronary vein stenosis: a report of two cases

Ahmet Vural, Teoman Kılıç, Ertan Ural, Dilek Ural
Kocaeli University Medical Faculty, Department Of Cardiology

Stenosis in the coronary veins can cause failure of left ventricular pacemaker lead implantation, which is the cornerstone of cardiac resynchronization therapy. There are several case reports in which left ventricular pacing could be possible after successful elimination of coronary vein stenosis by stent implantation or cutting balloon angioplasty. We report two cases of left ventricular pacemaker lead implantation after successful balloon angioplasty for posterolateral and posterior vein stenoses, respectively.

Keywords: Angioplasty, balloon, cardiomyopathy, dilated; coronary angiography; coronary stenosis/therapy; electrodes, implanted; heart failure; pacemaker, artificial.

How to cite this article
Ahmet Vural, Teoman Kılıç, Ertan Ural, Dilek Ural. Implantation of the left ventricular pacemaker lead after successful balloon angioplasty for coronary vein stenosis: a report of two cases. Turk Kardiyol Dern Ars. 2009; 37(3): 201-204

Corresponding Author: Teoman Kılıç, Türkiye
Manuscript Language: Turkish


Journal Metrics

Journal Citation Indicator: 0.18
CiteScore: 1.1
Source Normalized Impact
per Paper:
0.22
SCImago Journal Rank: 0.348

Quick Search

Copyright © 2024 Archives of the Turkish Society of Cardiology



Kare Publishing is a subsidiary of Kare Media.